Kontaktujte nás | Jazyk: čeština English
dc.title | Vztah mezi relaxovanou entalpií a objemem v průběhu fyzikálního stárnutí amorfních polymerů a selenu | cs |
dc.title | The relation between relaxed enthalpy and volume during physical aging of amorphous polymers and selenium | en |
dc.contributor.author | Říha, Pavel | |
dc.contributor.author | Rychwalski, Rodney | |
dc.contributor.author | Emri, Igor | |
dc.contributor.author | Sáha, Petr | |
dc.contributor.author | Kubát, Josef | |
dc.contributor.author | Slobodian, Petr | |
dc.relation.ispartof | European Polymer Journal | |
dc.identifier.issn | 0014-3057 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2006 | |
utb.relation.volume | 42 | |
utb.relation.issue | 10 | |
dc.citation.spage | 2824 | |
dc.citation.epage | 2837 | |
dc.type | article | |
dc.language.iso | en | |
dc.publisher | Elsevier Science B.V. | en |
dc.identifier.doi | 10.1016/j.eurpolymj.2006.06.003 | |
dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S0014305706001947 | |
dc.subject | entalpická a objemová relaxace | cs |
dc.subject | objemový modul | cs |
dc.subject | kompresibility | cs |
dc.subject | termické vlastnosti | cs |
dc.subject | vnitřní parametr | cs |
dc.subject | enthalpy and volume relaxation | en |
dc.subject | bulk modulus | en |
dc.subject | compressibility | en |
dc.subject | thermal properties | en |
dc.subject | internal parameter | en |
dc.description.abstract | Tento článek presentuje data pro PMMA, PMMA/PEO směsi, PC, PVC a PET. Zahrnuje i amorfní selen. Teplotní sestupné skoky z rovnováhy nad Tg na teploty pod Tg byly zkoumány. Relaxační entalpie a objem byly měřeny. Z relaxačních experimentů konstantní poměr Ka byl spočítán. Polymerní vzorky dávají hodnotu 2GPa, podobné hodnotě kompresibility v blízkosti Tg. Podobné výsledky byly dosaženy pro Se. | cs |
dc.description.abstract | This paper reports physical aging results for PMMA, PMMA/PEO blends, PS, PC, PVC, and PET (semicrystalline). Also included in this study is amorphous selenium. Temperature down-jumps from equilibrium above Tg to a temperature below Tg were carried out. Relaxed enthalpy, ?h, and volume contraction, ?v, were measured. From the aging records, the constant ratio ?h/?v=Ka was evaluated. For the polymeric samples Ka values of about 2 GPa were observed, thus similar to the inverse value of the isothermal compressibility close to Tg. Similarly for Se the Ka value obtained from ?h and ?v was in fair agreement with its isothermal compressibility. | en |
utb.faculty | Faculty of Technology | |
dc.identifier.uri | http://hdl.handle.net/10563/1000637 | |
utb.identifier.rivid | RIV/70883521:28110/06:63504667 | |
utb.identifier.obdid | 14555003 | |
utb.identifier.scopus | 2-s2.0-33748944315 | |
utb.identifier.wok | 000241460100068 | |
utb.source | j-riv | |
utb.contributor.internalauthor | Sáha, Petr | |
utb.contributor.internalauthor | Kubát, Josef | |
utb.contributor.internalauthor | Slobodian, Petr |