Kontaktujte nás | Jazyk: čeština English
dc.title | Vliv rychlosti chlazení na entalpickou a objemovou relaxaci polystyrenu | cs |
dc.title | Effect of cooling rate on enthalpy and volume relaxation of polystyrene | en |
dc.contributor.author | Hadač, Jiří | |
dc.contributor.author | Říha, Pavel | |
dc.contributor.author | Sáha, Petr | |
dc.contributor.author | Rychwalski, Rodney | |
dc.contributor.author | Emri, Igor | |
dc.contributor.author | Kubát, Josef | |
dc.contributor.author | Slobodian, Petr | |
dc.relation.ispartof | Journal of Non-Crystalline Solids | |
dc.identifier.issn | 0022-3093 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2007 | |
utb.relation.volume | 353 | |
utb.relation.issue | 28 | |
dc.citation.spage | 2681 | |
dc.citation.epage | 2691 | |
dc.type | article | |
dc.language.iso | en | |
dc.publisher | Elsevier Science B.V. | en |
dc.identifier.doi | 10.1016/j.jnoncrysol.2007.05.017 | |
dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S0022309307004838 | |
dc.subject | teplota skelného přechodu | cs |
dc.subject | rychlost chlazení | cs |
dc.subject | entalpická relaxace | cs |
dc.subject | objemová relaxace | cs |
dc.subject | objemový modul | cs |
dc.subject | fyzikální stárnutí | cs |
dc.subject | glass transition temperature | en |
dc.subject | cooling rate | en |
dc.subject | enthalpy relaxation | en |
dc.subject | volume relaxation | en |
dc.subject | physical aging | en |
dc.subject | bulk modulus | en |
dc.description.abstract | V tomto článku jsou presentovány výsledky fyzikálního stárnutí PS o úzké distribuci molekulových vah. Relaxovaná entalpie a objem jsou měřeny jako vliv rychlosti chlazení a teploty relaxace. Data jsou popsána TNM modelem a KWW relaxační funkcí. Poměr dh/dv dává hodnotu podobnou objemovému modulu, cca. 1.8GPa, přesahující teoretické předpoklady. | cs |
dc.description.abstract | This paper presents the results of measurements of physical aging on polystyrene with a narrow molecular weight distribution (Mw/Mn = 1.03). The evolution of the aging process was followed by recording the relaxed enthalpy and the accompanying decrease in volume, using differential scanning calorimetry and mercury-in-glass dilatometry, respectively. The measurements were carried out after cooling the sample at constant rate to the aging temperature. The cooling rate varied between 0.0037 and 1 °C/min. The aging data were fitted with the KWW and the TNM functions. The differences in the time scales of enthalpy, h, and volume, v, relaxation were relatively small. From the h(v) graphs the derivative dh/dv was found to amount to about 1.8 GPa, a value significantly exceeding the predictions of the thermodynamic model containing an additional internal variable. | en |
utb.faculty | Faculty of Technology | |
dc.identifier.uri | http://hdl.handle.net/10563/1000820 | |
utb.identifier.rivid | RIV/70883521:28110/07:63505436 | |
utb.identifier.obdid | 16553041 | |
utb.identifier.scopus | 2-s2.0-34447498888 | |
utb.identifier.wok | 000248925300001 | |
utb.source | j-riv | |
utb.contributor.internalauthor | Hadač, Jiří | |
utb.contributor.internalauthor | Sáha, Petr | |
utb.contributor.internalauthor | Kubát, Josef | |
utb.contributor.internalauthor | Slobodian, Petr |