Kontaktujte nás | Jazyk: čeština English
dc.title | Preparation of PE/PP blends with microfibrillar-phase morphology | en |
dc.contributor.author | Polášková, Martina | |
dc.contributor.author | Čermák, Roman | |
dc.contributor.author | Sedláček, Tomáš | |
dc.contributor.author | Obadal, Martin | |
dc.contributor.author | Sáha, Petr | |
dc.relation.ispartof | Proceedings of the 6th IASME/WSEAS International Conference on Heat Transfer, Thermal Engineering and Environment (HTE'08), Pts I and II | |
dc.identifier.isbn | 978-960-6766-97-8 | |
dc.date.issued | 2008 | |
dc.citation.spage | 511 | |
dc.citation.epage | 515 | |
dc.event.title | 6th IASME/WSEAS International Conference on Heat Transfer, Thermal Engineering and Environment | |
dc.event.location | Rhodes | |
utb.event.state-en | Greece | |
utb.event.state-cs | Řecko | |
dc.event.sdate | 2008-08-20 | |
dc.event.edate | 2008-08-22 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | World Scientific and Engineering Academy and Society (WSEAS) | en |
dc.relation.uri | http://www.wseas.us/e-library/conferences/2008/rhodes/hte/hte00.pdf | |
dc.subject | Biocompatible polymer blend | en |
dc.subject | Polyethylene | en |
dc.subject | Polypropylene | en |
dc.subject | In-situ composite | en |
dc.subject | Microfibrillar-phase morphology | en |
dc.description.abstract | Polyethylene/polypropylene blend extrudates with microfibrillar-phase morphology (polypropylene microfibrils reinforcing polyethylene matrix phase) were prepared through continuous extrusion with semihyperbolic-converging die enabling elongation and orientation of macromolecules in flow direction. Structure and thermal properties of extruded profiles were examined using electron microscopy, wide-angle X-ray scattering and differential scanning calorimetry. Tensile tests proved that extrudates with microfibrillar-phase morphology show significantly. higher mechanical properties than conventional extrudates. Presented concept offers possibility of expensive multicomponent medical devices with metal-inlays replacement. | en |
utb.faculty | Faculty of Technology | |
dc.identifier.uri | http://hdl.handle.net/10563/1001880 | |
utb.identifier.rivid | RIV/70883521:28110/08:63507003!RIV09-MPO-28110___ | |
utb.identifier.obdid | 43857032 | |
utb.identifier.wok | 000264214300080 | |
utb.source | d-wok | |
dc.date.accessioned | 2011-08-09T07:34:08Z | |
dc.date.available | 2011-08-09T07:34:08Z | |
utb.contributor.internalauthor | Polášková, Martina | |
utb.contributor.internalauthor | Čermák, Roman | |
utb.contributor.internalauthor | Sedláček, Tomáš | |
utb.contributor.internalauthor | Sáha, Petr |
Soubory | Velikost | Formát | Zobrazit |
---|---|---|---|
K tomuto záznamu nejsou připojeny žádné soubory. |