Publikace UTB
Repozitář publikační činnosti UTB

Utilizing of square wave voltammetry to detect flavonoids in the presence of human urine

Repozitář DSpace/Manakin

Zobrazit minimální záznam


dc.title Utilizing of square wave voltammetry to detect flavonoids in the presence of human urine en
dc.contributor.author Adam, Vojtěch
dc.contributor.author Mikelová, Radka
dc.contributor.author Hubálek, Jaromír
dc.contributor.author Hanuštiak, Pavel
dc.contributor.author Beklová, Miroslava
dc.contributor.author Hodek, Petr
dc.contributor.author Horna, Aleš
dc.contributor.author Trnková, Libuše
dc.contributor.author Stiborová, Marie
dc.contributor.author Zeman, Ladislav
dc.contributor.author Kizek, René
dc.relation.ispartof Sensors
dc.identifier.issn 1424-8220 Scopus Sources, Sherpa/RoMEO, JCR
dc.date.issued 2007-10
utb.relation.volume 7
utb.relation.issue 10
dc.citation.spage 2402
dc.citation.epage 2418
dc.type article
dc.language.iso en
dc.publisher Molecular Diversity Preservation International (MDPI) en
dc.identifier.doi 10.3390/s7102402
dc.relation.uri http://www.mdpi.com/1424-8220/7/10/2402/
dc.subject flavonoids en
dc.subject antioxidant en
dc.subject carbon paste electrode en
dc.subject square wave voltammetry en
dc.subject western blot analysis en
dc.subject cytochrome P450 en
dc.subject cancer en
dc.description.abstract About biological affecting of flavonoids on animal organisms is known less, thus we selected flavonoids, flavanones and flavones, and their glycosides, which were examined as potential inducers of cytochrome(s) P450 when administrated by gavages into experimental male rats. The study was focused on induction of CYP1A1, the major cytochrome P450 involved in carcinogen activation. The data obtained demonstrate the necessity of taking into account not only ability of flavonoids to bind to Ah receptor (induction factor) but also to concentrate on their distribution and metabolism (including colon microflora) in the body. After that we examined certain flavonoids as potential inducers of cytochrome P450, we wanted to suggest and optimize suitable electrochemical technique for determination of selected flavonoids (quercetin, quercitrin, rutin, chrysin and diosmin) in body liquids. For these purposes, we selected square wave voltannetry using carbon paste electrode. Primarily we aimed on investigation of their basic electrochemical behaviour. After that we have optimized frequency, step potential and supporting electrolyte. Based on the results obtained, we selected the most suitable conditions for determination of the flavonoids as follows: frequency 180 Hz, step potential 1.95 mV/s and phosphate buffer of pH 7 as supporting electrolyte. Detection limits (3 S/N) of the flavonoids were from units to tens of nM except diosmin, where the limit were higher than M. In addition, we attempted to suggest a sensor for analysis of flavonoids in urine. It clearly follows from the results obtained that flavonoids can be analysed in the presence of animal urine, because urine did not influence much the signals of flavonoids (recoveries of the signals were about 90 %). en
utb.faculty Faculty of Technology
dc.identifier.uri http://hdl.handle.net/10563/1002113
utb.identifier.obdid 43865391
utb.identifier.scopus 2-s2.0-36048938678
utb.identifier.wok 000250409400023
utb.source j-wok
dc.date.accessioned 2011-08-16T15:06:30Z
dc.date.available 2011-08-16T15:06:30Z
dc.rights Attribution 3.0 International
dc.rights.uri https://creativecommons.org/licenses/by/3.0/
dc.rights.access openAccess
utb.contributor.internalauthor Horna, Aleš
Find Full text

Soubory tohoto záznamu

Zobrazit minimální záznam

Attribution 3.0 International Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Attribution 3.0 International