Publikace UTB
Repozitář publikační činnosti UTB

Lactoferrin isolation using monolithic column coupled with spectrometric or micro-amperometric detector

Repozitář DSpace/Manakin

Zobrazit minimální záznam


dc.title Lactoferrin isolation using monolithic column coupled with spectrometric or micro-amperometric detector en
dc.contributor.author Adam, Vojtěch
dc.contributor.author Zítka, Ondřej
dc.contributor.author Doležal, Petr
dc.contributor.author Zeman, Ladislav
dc.contributor.author Horna, Aleš
dc.contributor.author Hubálek, Jaromír
dc.contributor.author Šílený, Jan
dc.contributor.author Křížková, Soňa
dc.contributor.author Trnková, Libuše
dc.contributor.author Kizek, René
dc.relation.ispartof Sensors
dc.identifier.issn 1424-8220 Scopus Sources, Sherpa/RoMEO, JCR
dc.date.issued 2008-01
utb.relation.volume 8
utb.relation.issue 1
dc.citation.spage 464
dc.citation.epage 487
dc.type article
dc.language.iso en
dc.publisher Molecular Diversity Preservation International (MDPI) en
dc.identifier.doi 10.3390/s8010464
dc.relation.uri http://www.mdpi.com/1424-8220/8/1/464/
dc.subject lactoferrin en
dc.subject milk protein en
dc.subject linear sweep voltammetry en
dc.subject screen-printed carbon electrode en
dc.subject electrochemistry en
dc.subject liquid chromatography en
dc.subject monolithic column en
dc.subject UV-VIS spectrometry en
dc.description.abstract Lactoferrin is a multifunctional protein with antimicrobial activity and others to health beneficial properties. The main aim of this work was to propose easy to use technique for lactoferrin isolation from cow colostrum samples. Primarily we utilized sodium dodecyl sulphate - polyacrylamide gel electrophoresis for isolation of lactoferrin from the real samples. Moreover we tested automated microfluidic Experion electrophoresis system to isolate lactoferrin from the collostrum sample. The well developed signal of lactoferrin was determined with detection limit ( 3 S/N) of 20 ng/ml. In spite of the fact that Experion is faster than SDS-PAGE both separation techniques cannot be used in routine analysis. Therefore we have tested third separation technique, ion exchange chromatography, using monolithic column coupled with UV-VIS detector (LC-UV-VIS). We optimized wave length ( 280 nm), ionic strength of the elution solution (1.5 M NaCl) and flow rate of the retention and elution solutions (0.25 ml/min and 0.75 ml/min. respectively). Under the optimal conditions the detection limit was estimated as 0.1 mu g/ml of lactoferrin measured. Using LC-UV-VIS we determined that lactoferrin concentration varied from 0.5 g/l to 1.1 g/l in cow colostrums collected in the certain time interval up to 72 hours after birth. Further we focused on miniaturization of detection device. We tested amperometric detection at carbon electrode. The results encouraged us to attempt to miniaturise whole detection system and to test it on analysis of real samples of human faeces, because lactoferrin level in faeces is closely associated with the inflammations of intestine mucous membrane. For the purpose of miniaturization we employed the technology of printed electrodes. The detection limit of lactoferrin was estimated as 10 mu g/ml measured by the screen-printed electrodes fabricated by us. The fabricated electrodes were compared with commercially available ones. It follows from the obtained results that the responses measured by commercial electrodes are app. ten times higher compared with those measured by the electrodes fabricated by us. This phenomenon relates with smaller working electrode surface area of the electrodes fabricated by us ( about 50%) compared to the commercial ones. The screen-printed electrodes fabricated by us were utilized for determination of lactoferrin faeces. Regarding to fact that sample of faeces was obtained from young and healthy man the amount of lactoferrin in sample was under the limit of detection of this method. en
utb.faculty Faculty of Technology
dc.identifier.uri http://hdl.handle.net/10563/1002118
utb.identifier.rivid RIV/70883521:28110/08:43865384!RIV12-MSM-28110___
utb.identifier.obdid 43865388
utb.identifier.scopus 2-s2.0-40849127115
utb.identifier.wok 000252628400026
utb.source j-wok
dc.date.accessioned 2011-08-16T15:06:31Z
dc.date.available 2011-08-16T15:06:31Z
dc.rights Attribution 3.0 International
dc.rights.uri https://creativecommons.org/licenses/by/3.0/
dc.rights.access openAccess
utb.contributor.internalauthor Horna, Aleš
Find Full text

Soubory tohoto záznamu

Zobrazit minimální záznam

Attribution 3.0 International Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Attribution 3.0 International