Publikace UTB
Repozitář publikační činnosti UTB

Approach for measuring the angle of hallux valgus

Repozitář DSpace/Manakin

Zobrazit minimální záznam


dc.title Approach for measuring the angle of hallux valgus en
dc.contributor.author Zhou, Jin
dc.contributor.author Hlaváček, Petr
dc.contributor.author Xu, Bo
dc.contributor.author Chen, Wuyong
dc.relation.ispartof Indian Journal of Orthopaedics
dc.identifier.issn 0019-5413 Scopus Sources, Sherpa/RoMEO, JCR
dc.date.issued 2013
utb.relation.volume 47
utb.relation.issue 3
dc.citation.spage 278
dc.citation.epage 282
dc.type article
dc.language.iso en
dc.publisher Medknow Publications and Media Pvt. Ltd. en
dc.identifier.doi 10.4103/0019-5413.109875
dc.relation.uri http://www.ijoonline.com/article.asp?issn=0019-5413;year=2013;volume=47;issue=3;spage=278;epage=282;aulast=Zhou
dc.subject angle of hallux valgus en
dc.subject foot print en
dc.subject Hallux valgus en
dc.subject radiography en
dc.subject three dimensional laser foot scanning en
dc.description.abstract Background: There is medium correlation between the current anthropometric method and the radiography in the angle of hallux valgus (AoH) measurement, so this study aimed at designing a reliable and more accurate approach to measure the AoH (AoH). Materials and Methods: Fifteen age, body weight, and height matched male students were included and those with foot disorders, deformities, or injuries were excluded from the study. The dorsal protrusions of the first metatarsal and the hallux were marked by palpating from three experienced observers; then their barefoot model in standing was collected by a three dimensional laser scanning system. The AoH was defined in the X-Y plane by the angle between the line joining the marks of centre of head and centre of base of metatarsal shaft and the one connecting the marks of the centre of metatarsal head and the hallux. The same procedure was repeated a week later. Besides, other measures based on the footprint, outline, and the radiography were also available for comparisons. Paired t-test, linear regression, and reliability analysis were applied for statistical analysis with significant level of 0.05 and 95% confidence interval. Results: There were no significant differences recorded between the new method and the radiographic method ( P = 0.069). The AoH was superior to the methods of footprint and outline and it displayed a relative higher correlation with the radiographic method (r = 0.94, r 2 = 0.89). Moreover both the inter and intraobserver reliabilities of this method were proved to be good. Conclusion: This new method can be used for hallux valgus inspection and evaluation. en
utb.faculty Faculty of Technology
dc.identifier.uri http://hdl.handle.net/10563/1003332
utb.identifier.obdid 43869917
utb.identifier.scopus 2-s2.0-84878435958
utb.identifier.wok 000323618600010
utb.identifier.coden INJOA
utb.source j-scopus
dc.date.accessioned 2013-07-27T14:55:06Z
dc.date.available 2013-07-27T14:55:06Z
dc.rights.access openAccess
utb.contributor.internalauthor Zhou, Jin
utb.contributor.internalauthor Hlaváček, Petr
Find Full text

Soubory tohoto záznamu

Zobrazit minimální záznam