Kontaktujte nás | Jazyk: čeština English
dc.title | Entangled network of carbon nanotubes embedded in polyurethane and its use for body kinematics and joint flexion sensing | en |
dc.contributor.author | Slobodian, Petr | |
dc.contributor.author | Říha, Pavel | |
dc.contributor.author | Sáha, Petr | |
dc.relation.ispartof | Materials and Applications for Sensors and Transducers II | |
dc.identifier.issn | 1013-9826 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.identifier.isbn | 978-3-03785-616-1 | |
dc.date.issued | 2013 | |
utb.relation.volume | 543 | |
dc.citation.spage | 39 | |
dc.citation.epage | 42 | |
dc.event.title | 2nd International Conference on Materials and Applications for Sensors and Transducers, IC-MAST | |
dc.event.location | Budapest | |
utb.event.state-en | Hungary | |
utb.event.state-cs | Maďarsko | |
dc.event.sdate | 2012-05-24 | |
dc.event.edate | 2012-05-28 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | Trans Tech Publications Inc. | en |
dc.identifier.doi | 10.4028/www.scientific.net/KEM.543.39 | |
dc.relation.uri | http://www.scientific.net/KEM.543.39 | |
dc.subject | Carbon nanotubes | en |
dc.subject | polyurethane | en |
dc.subject | strain sensor | en |
dc.subject | resistance | en |
dc.subject | biomechanics | en |
dc.description.abstract | Monitoring body kinematics and joint flexion has fundamental relevance in orthopedics and rehabilitation. The used sensing element is prepared from a highly-deformable polymer composite composed of a network of entangled electrically-conductive carbon nanotubes embedded in elastic polyurethane. The composite is prepared by an innovative procedure in which the non-woven polyurethane filtering membrane and the carbon nanotube cake are integrated by compression molding. As an example of the composite use as a strain sensor, human knee flexion and its cyclic movement is monitored, that may be applicable in athletic training as well as in orthopedics and rehabilitation. | en |
utb.faculty | Faculty of Technology | |
dc.identifier.uri | http://hdl.handle.net/10563/1003388 | |
utb.identifier.obdid | 43870399 | |
utb.identifier.scopus | 2-s2.0-84876360841 | |
utb.identifier.wok | 000319023100010 | |
utb.identifier.coden | KEMAE | |
utb.source | d-wok | |
dc.date.accessioned | 2013-07-27T14:55:37Z | |
dc.date.available | 2013-07-27T14:55:37Z | |
utb.contributor.internalauthor | Slobodian, Petr | |
utb.contributor.internalauthor | Sáha, Petr | |
utb.fulltext.affiliation | Petr Slobodian1,2,a, ; Pavel Riha3,b ; and Petr Saha1,2,c 1 T. Bata University, Faculty of Technology, Polymer Centre, 760 01 Zlin, Czech Republic 2 T. Bata University, Centre of Polymer Systems, University Institute, 760 01 Zlin, Czech Republic 3 Institute of Hydrodynamics, Academy of Sciences, 166 12 Prague 6, Czech Republic a:slobodian@ft.utb.cz b:riha@ih.cas.cz c:saha@utb.cz | |
utb.fulltext.dates | - | |
utb.fulltext.sponsorship | The work was supported by the Operational Program of Research and Development for Innovations co-funded by the European Regional Development Fund (ERDF), the National budget of Czech Republic within the framework of the Centre of Polymer Systems project (Reg. No.: CZ.1.05/2.1.00/03.0111). This article was also supported by the internal grant of TBU in Zlin No. IGA/FT/2012/022 funded from the resources of Specific University Research and by the Fund of Institute of Hydrodynamics AV0Z20600510. We appreciate also support and help provided by the company SPUR a.s. (Czech Republic) during preparation of polyurethane non-woven filters. | |
utb.fulltext.projects | CZ.1.05/2.1.00/03.0111 | |
utb.fulltext.projects | IGA/FT/2012/022 | |
utb.fulltext.projects | AV0Z20600510 | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.faculty | Faculty of Technology | |
utb.fulltext.ou | Centre of Polymer Systems | |
utb.fulltext.ou | Polymer Centre |