Kontaktujte nás | Jazyk: čeština English
dc.title | Dynamický rozptyl světla v analýze koloidních systémů | cs |
dc.title | Dynamic light scattering in analysis of colloidal systems | en |
dc.contributor.author | Ševčíková, Petra | |
dc.contributor.author | Kašpárková, Věra | |
dc.contributor.author | Krejčí, Jiří | |
dc.contributor.author | Vltavská, Pavlína | |
dc.relation.ispartof | Chemické listy | |
dc.identifier.issn | 1213-7103 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.identifier.issn | 0009-2770 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2014 | |
utb.relation.volume | 108 | |
utb.relation.issue | 5 | |
dc.citation.spage | 479 | |
dc.citation.epage | 482 | |
dc.type | article | |
dc.language.iso | cs | |
dc.publisher | Česká společnost chemická (ČSCH) | |
dc.relation.uri | http://www.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/506 | |
dc.relation.uri | http://www.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/download/506/506/506 | |
dc.description.abstract | Dynamic light scattering (DLS) is a non-invasive technique, capable of measuring the size of submicron particles in the submicron range. The study was focused on the applicability of DLS in measurement of colloidal particles of different types. The micelle sizes of surfactants (Tween 60, Tween 20, Igepal CA 720 and Na lauryl sarcosinate) and particle sizes of micro-and nanoemulsions were measured. The diameters of surfactant micelles were 13.0±0.1 nm, 8.4±0.1 nm, 7.1±0.2 nm and 2.7±0.1 nm for Tween 60, Tween 20, Igepal CA 720 and Na lauryl sarcosinate, respectively. Stability of nanoemulsions as a consequence of the changes of particle size distributions in storage was monitored. The results revealed the presence of uni-, bi-and trimodal distributions reflecting the occurrence of various particle populations as well as a shift of distribution curves due to the particle growth. It was confirmed that DLS can provide reliable and rapid determinations of particle sizes of micro-, nano-and classical emulsions. | en |
utb.faculty | University Institute | |
utb.faculty | Faculty of Technology | |
dc.identifier.uri | http://hdl.handle.net/10563/1003771 | |
utb.identifier.obdid | 43871989 | |
utb.identifier.scopus | 2-s2.0-84901698533 | |
utb.identifier.wok | 000338424600010 | |
utb.identifier.coden | CHLSA | |
utb.source | j-scopus | |
dc.date.accessioned | 2014-07-07T13:43:50Z | |
dc.date.available | 2014-07-07T13:43:50Z | |
utb.ou | Centre of Polymer Systems | |
utb.contributor.internalauthor | Ševčíková, Petra | |
utb.contributor.internalauthor | Kašpárková, Věra | |
utb.contributor.internalauthor | Krejčí, Jiří | |
utb.contributor.internalauthor | Vltavská, Pavlína | |
utb.fulltext.affiliation | PETRA ŠEVČÍKOVÁ a, VĚRA KAŠPÁRKOVÁ a,b, JIŘÍ KREJČÍ a a PAVLÍNA VLTAVSKÁ a a Ústav technologie tuků, tenzidů a kosmetiky, Fakulta technologická, Univerzita Tomáše Bati ve Zlíně, nám. T. G. Masaryka 275, 760 01 Zlín, b Centrum polymerních systémů, Univerzitní institut, Univerzita Tomáše Bati ve Zlíně, Nad Ovčírnou 3685, 760 01 Zlín psevcikova@ft.utb.cz, vkasparkova@ft.utb.cz | |
utb.fulltext.dates | Došlo 18.4.13 přijato 14.6.13. | |
utb.fulltext.sponsorship | Tento článek byl vytvořen za podpory Operačního programu Výzkum a vývoj pro inovace, jenž je spolufinancován Evropským fondem pro regionální rozvoj (ERDF) a státním rozpočtem České republiky, v rámci projektu Centra polymerních systémů (CZ.1.05/2.1.00/03.0111). Tato práce vznikla také za podpory interního grantu UTB ve Zlíně č. IGA/FT/2013/016 financovaného z prostředků specifického vysokoškolského výzkumu. | |
utb.fulltext.projects | CZ.1.05/2.1.00/03.011 | |
utb.fulltext.projects | IGA/FT/2013/016 | |
utb.fulltext.faculty | Faculty of Technology | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.ou | Department of Fat, Surfactant and Cosmetics Technology | |
utb.fulltext.ou | Centre of Polymer Systems |