Kontaktujte nás | Jazyk: čeština English
dc.title | Remote control of electrical appliances via power line 230V | en |
dc.contributor.author | Adámek, Milan | |
dc.contributor.author | Martinec, Pavel | |
dc.contributor.author | Matýsek, Miroslav | |
dc.relation.ispartof | Annals of DAAAM and Proceedings of the International DAAAM Symposium | |
dc.identifier.issn | 1726-9679 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.identifier.isbn | 978-3-901509-70-4 | |
dc.date.issued | 2009 | |
utb.relation.volume | 20 | |
dc.citation.spage | 1505 | |
dc.citation.epage | 1506 | |
dc.event.title | Annals of DAAAM for 2009 and 20th International DAAAM Symposium Intelligent Manufacturing and Automation: Focus on Theory | |
dc.event.location | Vienna | |
utb.event.state-en | Austria | |
utb.event.state-cs | Rakousko | |
dc.event.sdate | 2009-11-25 | |
dc.event.edate | 2009-11-28 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | Danube Adria Association for Automation and Manufacturing (DAAAM) | |
dc.subject | power line | en |
dc.subject | remote control | en |
dc.subject | wireless | en |
dc.subject | data transfer | en |
dc.description.abstract | The submitted work deals with problems of data transfer via power line 230 V for purposes of remote control electrical appliances. In this work were designed devices which provide relative communication via power line within the frame of the one-family house. Designed devices concretely input-output unit, PC interface and GSM gate work on a bus principle. The bus is constructed by power line 230 V. Designed devices are composed of microcontrollers AVR and modem TDA5051AT provides their relative communication via power line. Communications protocol with which devices work was developed so that corresponds with hardware resolution of particular devices. Particular devices were practically realized and their activity was checked up. | en |
utb.faculty | Faculty of Applied Informatics | |
dc.identifier.uri | http://hdl.handle.net/10563/1004042 | |
utb.identifier.obdid | 43859591 | |
utb.identifier.scopus | 2-s2.0-84904314870 | |
utb.identifier.wok | 000282335600753 | |
utb.source | d-scopus | |
dc.date.accessioned | 2015-01-15T13:20:09Z | |
dc.date.available | 2015-01-15T13:20:09Z | |
dc.rights.uri | https://open.k.utb.cz/blog/2021/04/19/daaam/ | |
dc.rights.access | openAccess | |
utb.contributor.internalauthor | Adámek, Milan | |
utb.contributor.internalauthor | Martinec, Pavel | |
utb.contributor.internalauthor | Matýsek, Miroslav | |
utb.fulltext.affiliation | Adámek Milan Faculty of Applied Informatics Nad Stráněmi 45 11, Zlín Czech Republic Martinec Pavel Faculty of Applied Informatics Nad Stráněmi 45 11, Zlín Czech Republic Matýsek Miroslav Faculty of Applied Informatics Nad Stráněmi 45 11, Zlín Czech Republic | |
utb.fulltext.dates | - | |
utb.fulltext.references | [1] Burkhard, M. 2003. C for microcontrollers. Prague, Czech Republic: BEN, 2003, 280. 80-7300-077-6. [2] Flajzar, T. 2005. GSM alarm – transfer via mobile phone. Prague, Czech Republic: BEN, 2005, 84. 80-7300-183-7. [3] Horst, J. 2004. Informative and telekommunication technology. Prague, Czech Republic:Europa-Sobotáles, 2004. 399. 80-86706-08-7. | |
utb.fulltext.sponsorship | This work was supported by the Ministry of Education of the Czech Republic in the range of research projects No. MSM 7088352102. |