Publikace UTB
Repozitář publikační činnosti UTB

Use of relocation device at scanning of polymeric material surface quality

Repozitář DSpace/Manakin

Zobrazit minimální záznam


dc.title Use of relocation device at scanning of polymeric material surface quality en
dc.contributor.author Pata, Vladimír
dc.contributor.author Řezníček, Martin
dc.contributor.author Sýkorová, Libuše
dc.contributor.author Knedlová, Jana
dc.contributor.author Malachová, Martina
dc.relation.ispartof Applied Mechanics and Materials
dc.identifier.issn 1660-9336 Scopus Sources, Sherpa/RoMEO, JCR
dc.date.issued 2014
utb.relation.volume 693
dc.citation.spage 243
dc.citation.epage 246
dc.type article
dc.language.iso en
dc.publisher Trans Tech Publications Ltd.
dc.identifier.doi 10.4028/www.scientific.net/AMM.693.243
dc.relation.uri http://www.scientific.net/AMM.693.243
dc.subject CO<inf>2</inf> laser en
dc.subject Density of Points on the surface roughness en
dc.subject Micromachining en
dc.subject PMMA en
dc.subject Regression equations en
dc.subject Technological parameters en
dc.subject TEM00 mode en
dc.subject The theory of hypotheses en
dc.description.abstract Nowadays, manufacturers and users of parts made of polymeric materials make increasing demands on surface quality of these parts. In order to fulfill these claims, it is necessary to use not only the quality measurement systems for surface quality inspection, but also suitable products that allow to set up the inspected polymeric component properly set up to the measuring system scanner. However, it is not sufficient. Due to the requirements of the customers or the production it is often necessary to repeat the surface quality measurement, which is more and more often done in 3D; that might be quite difficult. Except for special cases there should not be any marks done by the inspection workplace which might lower the inspected surface quality. Therefore it is not suitable to make mechanical marks such as scratch, ridge, etc. On the other hand, other types of marks done by non-invasive method, such as sticking paper marks, measuring cross, etc. is also not admissible as there might result in surface damage due to adhesive forces as well by mechanical or chemical processes. Thus it is necessary to take into account the fact that parts made of polymeric material can be so small that none of the above mentioned methods that are widely used nowadays cannot be applied just because of the dimensional reason. © (2014) Trans Tech Publications, Switzerland. en
utb.faculty Faculty of Technology
dc.identifier.uri http://hdl.handle.net/10563/1004594
utb.identifier.obdid 43873573
utb.identifier.scopus 2-s2.0-84929428098
utb.source j-scopus
dc.date.accessioned 2015-06-02T08:13:03Z
dc.date.available 2015-06-02T08:13:03Z
utb.contributor.internalauthor Pata, Vladimír
utb.contributor.internalauthor Řezníček, Martin
utb.contributor.internalauthor Sýkorová, Libuše
utb.contributor.internalauthor Knedlová, Jana
utb.contributor.internalauthor Malachová, Martina
Find Full text

Soubory tohoto záznamu

Zobrazit minimální záznam