dc.title | Micro-hardness and morphology of LDPE influenced by beta radiation | en |
dc.contributor.author | Ovsík, Martin | |
dc.contributor.author | Krátký, Petr | |
dc.contributor.author | Maňas, David | |
dc.contributor.author | Maňas, Miroslav | |
dc.contributor.author | Staněk, Michal | |
dc.contributor.author | Bednařík, Martin | |
dc.relation.ispartof | Key Engineering Materials | |
dc.identifier.issn | 1013-9826 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.identifier.isbn | 9783038350620 | |
dc.date.issued | 2014 | |
utb.relation.volume | 606 | |
dc.citation.spage | 253 | |
dc.citation.epage | 256 | |
dc.event.title | 10th International Conference on Local Mechanical Properties, LMP 2013 | |
dc.event.location | Kutná Hora | |
utb.event.state-en | Czech Republic | |
utb.event.state-cs | Česká republika | |
dc.event.sdate | 2013-11-06 | |
dc.event.edate | 2013-11-08 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | Trans Tech Publications Ltd | |
dc.identifier.doi | 10.4028/www.scientific.net/KEM.606.253 | |
dc.relation.uri | https://www.scientific.net/KEM.606.253 | |
dc.subject | Cross - linking | en |
dc.subject | Depth Sensing Indentation | en |
dc.subject | Irradiation | en |
dc.subject | Micro-hardness | en |
dc.subject | Polyethylene | en |
dc.description.abstract | This article deals with the influence of different doses of Beta radiation to the structure and mico-mechanical properties of Low-density polyethylene (LDPE). Hard surface layers of polymer materials, especially LDPE, can be formed by radiation cross-linking by β - radiation with doses of 33, 66 and 99 kGy. Material properties created by β - radiation are measured by microhardness test using the DSI method (Depth Sensing Indentation). Individual radiation doses caused structural and micro-mechanical changes which have a significant effect on the final properties of the LDPE tested. The highest values of micro-mechanical properties were reached at radiation dose of 66 and 99 kGy, when the micro-hardness values increased by about 21%. The changes were examined and confirmed by X-ray diffraction. © (2014) Trans Tech Publications, Switzerland. | en |
utb.faculty | Faculty of Technology | |
dc.identifier.uri | http://hdl.handle.net/10563/1004638 | |
utb.identifier.obdid | 43871855 | |
utb.identifier.scopus | 2-s2.0-84898847983 | |
utb.identifier.coden | KEMAE | |
utb.source | d-scopus | |
dc.date.accessioned | 2015-06-04T12:54:38Z | |
dc.date.available | 2015-06-04T12:54:38Z | |
utb.contributor.internalauthor | Ovsík, Martin | |
utb.contributor.internalauthor | Krátký, Petr | |
utb.contributor.internalauthor | Maňas, David | |
utb.contributor.internalauthor | Maňas, Miroslav | |
utb.contributor.internalauthor | Staněk, Michal | |
utb.contributor.internalauthor | Bednařík, Martin |