Evaluation of the sheepskin mattress in terms of pressure relieving capability

Repozitář DSpace/Manakin

Zobrazit minimální záznam


dc.title Evaluation of the sheepskin mattress in terms of pressure relieving capability en
dc.contributor.author Zhou, Jin
dc.contributor.author Tang, Qiuyue
dc.contributor.author Zhang, Youran
dc.contributor.author Yu, Weicai
dc.contributor.author Gaidǎu, Carmen
dc.contributor.author Chen, Wuyong
dc.relation.ispartof Proceedings of the 4th International Conference on Advanced Materials and Systems, ICAMS 2012
dc.date.issued 2012
dc.citation.spage 395
dc.citation.epage 400
dc.event.title 4th International Conference on Advanced Materials and Systems, ICAMS 2012
dc.event.location Bucharest
utb.event.state-en Romania
utb.event.state-cs Rumunsko
dc.event.sdate 2012-09-27
dc.event.edate 2012-09-29
dc.type conferenceObject
dc.language.iso en
dc.subject Pressure measurement en
dc.subject Sheepskin mattress en
dc.subject Ulceration prevention. en
dc.description.abstract The aim of this study was to quantitatively evaluate the effectiveness of sheepskin mattress in pressure relieving. The pressure distribution of rigid mattress (CM), air mattress (AM) and standard medical mattress (SMM) in supine posture of 18 students before and after the intervention of the own-made sheepskin mattress (FM) were measured by mFLEX system and variables of peak pressure (PP) and average pressure (mmHg) (AP) and contact area (cm2) (CA) at total, back, sacrum and heel area were used for comparisons. Paired-T test with a significant level of 0.05 shows that the usage of FM significantly increased total CA by mean of 30% for three basis mattresses, then reductions about 8% for PP and 10% to 40% for AP were also observed. At back area, both PP and AP decreased by average of 30% for CM and AM; whereas only 10% reducing of PP was reported at sacrum for CM and SMM but at which the magnitude of pressure was still high. With exception of heel area, the outcomes were proved to be reliable where CoV and ICC ranged 5.1%-23.2% and 0.70-0.97. It can be concluded that the sheep skin mattress was effective in relieving the magnitude of contact pressure and it could be used in the routine patient's care to prevent the ulceration. en
utb.faculty Faculty of Technology
dc.identifier.uri http://hdl.handle.net/10563/1004682
utb.identifier.scopus 2-s2.0-84888259529
utb.source d-scopus
dc.date.accessioned 2015-06-04T12:54:50Z
dc.date.available 2015-06-04T12:54:50Z
utb.contributor.internalauthor Zhou, Jin
Find Full text

Soubory tohoto záznamu

Zobrazit minimální záznam