dc.title Comparison of the results of creep and micro - Indentation creep to irradiated HDPE en
dc.contributor.author Řezníček, Martin
dc.contributor.author Ovsík, Martin
dc.contributor.author Bednařík, Martin
dc.contributor.author Krátký, Petr
dc.contributor.author Maňas, David
dc.relation.ispartof Key Engineering Materials
dc.identifier.issn 1013-9826 Scopus Sources, Sherpa/RoMEO, JCR
dc.identifier.isbn 978-3-03835-555-7
dc.date.issued 2015
utb.relation.volume 662
dc.citation.spage 233
dc.citation.epage 236
dc.event.title 11th International Conference on Local Mechanical Properties, LMP 2014
dc.event.location High Tatras
utb.event.state-en Slovakia
utb.event.state-cs Slovensko
dc.event.sdate 2014-11-12
dc.event.edate 2014-11-14
dc.type conferenceObject
dc.language.iso en
dc.publisher Trans Tech Publications Ltd.
dc.identifier.doi 10.4028/www.scientific.net/KEM.662.233
dc.relation.uri http://www.scientific.net/KEM.662.233
dc.subject Compare en
dc.subject Creep en
dc.subject Depth Sensing indentation en
dc.subject Evaluation en
dc.subject Indentation creep en
dc.description.abstract The main goal of this paper is to compare measurements of creep behavior of Crosslinking polymer materials. Creep properties have been measured by two methods, first is micro-indentation with Depth Sensing Indention (DSI) and the second method is long-term creep test in room temperature. These rather different methods enable better analyis of the influence of radiation crosslinking, and therefore better define the appropriate dose of radiation with respect to the use of polymer materials in practice. The evaluation criteria for DSI test is index CIT [%]. The evaluation criteria for the standard creep test is the value of average elongation at the end of the test. When comparing these two values is then possible to see a slight effect on the radiation dose for the standard creep test, which showed mikrocreepu only slightly.[1,2] © (2015) Trans Tech Publications, Switzerland. en
utb.faculty Faculty of Technology
dc.identifier.uri http://hdl.handle.net/10563/1005796
utb.identifier.obdid 43874007
utb.identifier.scopus 2-s2.0-84952328426
utb.identifier.coden KEMAE
utb.source d-scopus
dc.date.accessioned 2016-04-12T11:51:57Z
dc.date.available 2016-04-12T11:51:57Z
dc.description.sponsorship TA03010724, TA CR, Technologická Agentura České Republiky
utb.contributor.internalauthor Řezníček, Martin
utb.contributor.internalauthor Ovsík, Martin
utb.contributor.internalauthor Bednařík, Martin
utb.contributor.internalauthor Krátký, Petr
utb.contributor.internalauthor Maňas, David
utb.fulltext.affiliation Martin Reznicek 1,a*, Martin Ovsik 1,b, Martin Bednarik 1,c, Petr Kratky 1,d, David Manas 1,e 1 Tomas Bata University in Zlin, Nam. T.G. Masaryka 5555, Zlín, 760 01 Czech Republic a mreznicek@ft.utb.cz*, b ovsik@ft.utb.cz, c mbednarik@ft.utb.cz, d pkratky@ft.utb.cz, e dmanas@ft.utb.cz
utb.fulltext.dates Submitted: 2014-11-28 Revised: 2015-03-18 Accepted: 2015-05-05 Online: 2015-09-11