Kontaktujte nás | Jazyk: čeština English
dc.title | Examining pharmaceuticals using terahertz spectroscopy | en |
dc.contributor.author | Sulovská, Kateřina | |
dc.contributor.author | Křesálek, Vojtěch | |
dc.relation.ispartof | Proceedings of SPIE - The International Society for Optical Engineering | |
dc.relation.ispartof | Millimetre Wave and Terahertz Sensors and Technology VII | |
dc.identifier.issn | 0277-786X Scopus Sources, Sherpa/RoMEO, JCR | |
dc.identifier.isbn | 978-1-62841-861-3 | |
dc.date.issued | 2015 | |
utb.relation.volume | 9651 | |
dc.event.title | Conference on Millimetre Wave and Terahertz Sensors and Technology VIII | |
dc.event.location | Toulouse | |
utb.event.state-en | France | |
utb.event.state-cs | Francie | |
dc.event.sdate | 2015-09-22 | |
dc.event.edate | 2015-09-22 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | International Society for Optical Engineering (SPIE) | |
dc.identifier.doi | 10.1117/12.2194585 | |
dc.subject | absorbance | en |
dc.subject | pharmaceuticals | en |
dc.subject | pseudoephedrine | en |
dc.subject | Terahertz time-domain spectroscopy | en |
dc.subject | transmittance | en |
dc.description.abstract | Pharmaceutical trafficking is common issue in countries where they are under stricter dispensing regime with monitoring of users. Most commonly smuggled pharmaceuticals include trade names Paralen Plus, Modafen, Clarinase repetabs, Aspirin complex, etc. These are transported mainly from Eastern Europe (e.g. Poland, Ukraine, Russia) to countries like Czech Republic, which is said to have one of the highest number of methamphetamine producers in Europe. The aim of this paper is to describe the possibility of terahertz spectroscopy utilization as an examining tool to distinguish between pharmaceuticals containing pseudoephedrine compounds and those without it. Selected medicaments for experimental part contain as an active ingredient pseudoephedrine hydrochloride or pseudoephedrine sulphate. Results show a possibility to find a pseudoephedrine compound spectra in samples according to previously computed and experimentally found ones, and point out that spectra of same brand names pills may vary according to their expiration date, batch, and amount of absorbed water vapours from ambience. Mislead spectrum also occurs during experimental work in a sample without chosen active ingredient, which shows persistent minor inconveniences of terahertz spectroscopy. All measurement were done on the TPS Spectra 3000 instrument. © 2015 COPYRIGHT SPIE. | en |
utb.faculty | Faculty of Applied Informatics | |
dc.identifier.uri | http://hdl.handle.net/10563/1006269 | |
utb.identifier.obdid | 43873318 | |
utb.identifier.scopus | 2-s2.0-84958609108 | |
utb.identifier.wok | 000368733700002 | |
utb.identifier.coden | PSISD | |
utb.source | d-scopus | |
dc.date.accessioned | 2016-04-28T10:53:20Z | |
dc.date.available | 2016-04-28T10:53:20Z | |
utb.contributor.internalauthor | Sulovská, Kateřina | |
utb.contributor.internalauthor | Křesálek, Vojtěch | |
utb.fulltext.affiliation | Kateřina Sulovská *a, Vojtěch Křesálek a a Tomas Bata University in Zlín, Faculty of Applied Informatics, Department of Electronics and Measurement, nám. T. G. Masaryka 5555, 760 01 Zlín, Czech Republic | |
utb.fulltext.dates | - | |
utb.fulltext.faculty | Faculty of Applied Informatics | |
utb.fulltext.faculty | Faculty of Applied Informatics | |
utb.fulltext.ou | Department of Electronics and Measurements | |
utb.fulltext.ou | Department of Electronics and Measurements |