Kontaktujte nás | Jazyk: čeština English
dc.title | Terahertz time-domain spectroscopy for studying absorbable hemostats | en |
dc.contributor.author | Nedvědová, Marie | |
dc.contributor.author | Křesálek, Vojtěch | |
dc.contributor.author | Adamík, Zdeněk | |
dc.contributor.author | Provazník, Ivo | |
dc.relation.ispartof | IEEE Transactions on Terahertz Science and Technology | |
dc.identifier.issn | 2156-342X Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2016 | |
utb.relation.volume | 6 | |
utb.relation.issue | 3 | |
dc.citation.spage | 420 | |
dc.citation.epage | 426 | |
dc.type | article | |
dc.language.iso | en | |
dc.publisher | IEEE Microwave Theory and Techniques Society | |
dc.identifier.doi | 10.1109/TTHZ.2016.2537149 | |
dc.relation.uri | http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7438938 | |
dc.subject | Absorbable hemostat | en |
dc.subject | kinetics | en |
dc.subject | physiological saline solution (PSS) | en |
dc.subject | terahertz (THz) time-domain spectroscopy | en |
dc.description.abstract | This study deals with the kinetics of absorbable hemostats used for supporting the hemostasis and wound closure during surgical intervention. There are several types of hemostats of different composition therefore with different mechanism of action. Here, terahertz (THz) time-domain spectroscopy is used for studying the absorption kinetics of the reactions between the hemostatic and the physiological saline solution (PSS). The reactions correspond with the changes of the THz radiation response measured in time. These time dependences are analyzed to find time constants for mathematical description of the hemostatic kinetics and the significant differences among all types of hemostats are found. The physiological saline solution is replaced by human blood in the additional measurement. Based on the results, we can compare the reaction rate of different types of hemostats that could be beneficial in the surgery practice. © 2016 IEEE. | en |
utb.faculty | Faculty of Applied Informatics | |
dc.identifier.uri | http://hdl.handle.net/10563/1006530 | |
utb.identifier.obdid | 43875477 | |
utb.identifier.scopus | 2-s2.0-84978010070 | |
utb.identifier.wok | 000379752200010 | |
utb.source | j-scopus | |
dc.date.accessioned | 2016-08-09T14:02:54Z | |
dc.date.available | 2016-08-09T14:02:54Z | |
dc.description.sponsorship | Ministry of Education, Youth and Sports of the Czech Republic within the National Sustainability Programme [LO1303 (MSMT-7778/2014)]; internal excellence project "Technical Science for Secure Society" | |
utb.contributor.internalauthor | Nedvědová, Marie | |
utb.contributor.internalauthor | Křesálek, Vojtěch | |
utb.contributor.internalauthor | Adamík, Zdeněk | |
utb.fulltext.affiliation | Marie Nedvedova, Vojtech Kresalek, Zdenek Adamik, Ivo Provaznik University of Technology, Brno, Czech Republic, Department of Electronics and Measurements, Tomas Bata University, Zlin, Czech Republic Chalmers University, Göteborg, Sweden. Faculty of Technology in Zlin. Palacký University, Olomouc, Czech Republic, Maternity and Gynecological Detachment of Tomas Bata Regional Hospital in Zlin, Department of Health Care Sciences in Tomas Bata University, Zlin, Czech Republic. University of Technology, Brno, Czech Republic, Department of Biomedical Engineering | |
utb.fulltext.dates | received December 04, 2015 revised January 29, 2016 and February 25, 2016 accepted February 25, 2016 Date of publication March 22, 2016 date of current version June 14, 2016 | |
utb.fulltext.faculty | Faculty of Technology | |
utb.fulltext.ou | Department of Electronics and Measurements | |
utb.fulltext.ou | Department of Health Care Sciences |