Kontaktujte nás | Jazyk: čeština English
dc.title | Micro-pulse stimulation | en |
dc.contributor.author | Nedvědová, Marie | |
dc.contributor.author | Chmelař, Milan | |
dc.contributor.author | Provazník, Ivo | |
dc.contributor.author | Řezníček, Zdeněk | |
dc.relation.ispartof | Lecture Notes in Electrical Engineering | |
dc.identifier.issn | 1876-1100 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.identifier.isbn | 978-3-319-53933-1 | |
dc.date.issued | 2018 | |
utb.relation.volume | 428 | |
dc.citation.spage | 13 | |
dc.citation.epage | 19 | |
dc.event.title | 1st International Conference on Applied Physics, System Science and Computers, APSAC 2016 | |
dc.event.location | Dubrovnik | |
utb.event.state-en | Croatia | |
utb.event.state-cs | Chorvatsko | |
dc.event.sdate | 2016-09-28 | |
dc.event.edate | 2016-09-30 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | Springer Verlag | |
dc.identifier.doi | 10.1007/978-3-319-53934-8_2 | |
dc.relation.uri | https://link.springer.com/chapter/10.1007/978-3-319-53934-8_2 | |
dc.subject | Burst therapy | en |
dc.subject | High-voltage pulsed current therapy | en |
dc.subject | Micro-pulse stimulation | en |
dc.subject | Subthreshold stimulation | en |
dc.description.abstract | This paper deals with a new electrotherapeutic method for use in physiatric treatment. The micro-pulse stimulation is based on the combination of three electrotherapeutic methods: burst therapy, high-voltage pulsed current therapy, and microelectrostimulation. Micro-pulse stimulation is special for its unusual configuration of pulse parameters; high-voltage electric pulses are safely used as a result of a cumulative effect of the subthreshold monophasic pulses with a very short duration. This combination of parameters should connect the advantages of used methods. This includes an analgesic effect without any obvious adaptation of the stimulated tissue and making the tissue penetration easier. As the micro-pulse stimulation was designed especially for the treatment of swelling and pain in animal therapy, the device is small, portable, battery-operated and easy to use. © Springer International Publishing AG 2018. | en |
utb.faculty | Faculty of Applied Informatics | |
dc.identifier.uri | http://hdl.handle.net/10563/1007290 | |
utb.identifier.obdid | 43877861 | |
utb.identifier.scopus | 2-s2.0-85026750553 | |
utb.identifier.wok | 000433970200002 | |
utb.source | d-scopus | |
dc.date.accessioned | 2017-09-03T21:40:09Z | |
dc.date.available | 2017-09-03T21:40:09Z | |
dc.description.sponsorship | Hybrid Integrated Technologies, Ltd.; Brno University of Technology; European Regional Development Fund under the project CEBIA-Tech Instrumentation [CZ.1.05/2.1.00/19.0376] | |
utb.contributor.internalauthor | Nedvědová, Marie | |
utb.fulltext.affiliation | Marie Nedvedova, Milan Chmelar, Ivo Provaznik and Zdenek Reznicek M. Nedvedova ( ✉ ) ⋅ M. Chmelar ⋅ I. Provaznik Faculty of Electrical Engineering and Communication, Department of Biomedical Engineering, Brno University of Technology, Technicka 3082/12, 61600 Brno, Czech Republic e-mail: tobolova@fai.utb.cz M. Nedvedova Faculty of Applied Informatics, Department of Electronics and Measurements, Tomas Bata University in Zlin, Nad Stranemi 4511, 76005 Zlin, Czech Republic Z. Reznicek Hybrid Integrated Technologies, Ltd., Nedachlebice 233, 68715 Nedachlebice, Czech Republic | |
utb.fulltext.dates | - | |
utb.fulltext.references | 1. Podebradsky, J., Vareka, I.: Fyzikální terapie I. Grada Publishing, Praha (1998) 2. Podebradsky, J., Vareka, I.: Fyzikální terapie II. Grada Publishing, Praha (1998) 3. Capko, J.: Základy fyziatrické léčby. Grada Publishing, Praha (1998) 4. Plonsey, R., Barr, R.C.: Bioelectricity: a Quantitative Approach. Springer, New York (2007) 5. Mercola, J.M., Kirsch, D.L.: The basis for microcurrent electrical therapy in conventional medical practice. J. Adv. Med. 8, 107–120 (1995) 6. Poltawski, L., Watson, T.: Bioelectricity and microcurrent therapy for tissue healing—a narrative review. Phys. Ther. Rev. 14, 104–114 (2009) 7. Butcher, M.: How to use POSiFECT ® bio-electric stimulation therapy in chronic wounds. Wound Essentials 2, 186–193 (2007) 8. De Gaspi, F.O. et al.: Effects of the topical application of hydroalcoholic leaf extract of Oncidium flexuosum Sims. (Orchidaceae) and Microcurrent on the healing of wounds surgically induced in Wistar rats. Evid. Based Complement. Altern. Med. 1–9 (2011) 9. Lee, B.Y., et al.: Ultra-low microcurrent in the management of diabetes mellitus, hypertension and chronic wounds: Report of twelve cases and discussion of mechanism of action. Int. J. Med. Sci. 7, 29–35 (2010) 10. Park, R., et al.: The effect of wearing shoes generating micro-currents on body composition and blood lipid concentrations of overweight females. J. Phys. Ther. Sci. 23, 177–180 (2011) 11. Lee, J., et al.: The effects of microcurrents on inflammatory reaction induced by ultraviolet irradiation. J. Phys. Ther. Sci. 23, 693–696 (2011) 12. Gossrau, G., et al.: Microcurrent transcutaneous electric nerve stimulation in painful diabetic neuropathy: A randomized placebo-controlled study. Pain Med. 12, 953–960 (2011) 13. Lin, Y., Van Weeren, P.R., et al.: Effect of microcurrent electrical tissue stimulation on equine tenocytes in culture. Am. J. Vet. Res. 67, 271–276 (2006) 14. Karnes, J., et al.: High-voltage pulsed current: Its influence on diameters of histamine-dilated arterioles in hamster cheek pouches. Arch. Phys. Med. Rehabil. 76, 381–386 (1995) 15. Kloth, L.C., Feedar, J.A.: Acceleration of Wound Healing with High Voltage, Monophasic, Pulsed Current. Phys. Ther. 68, 503–508 (1988) 16. Franek, A., Polak, A., Kucharzewski, M.: Modern application of high voltage stimulation for enhanced healing of venous crural ulceration. Med. Eng. Phys. 22, 647–655 (2000) 17. Burdge, J.J., Hartman, J.F., Wright, M.L.: A retrospective study of highvoltage, pulsed current as an adjunctive therapy in limb salvage for chronic diabetic wounds of the lower extremity. Ostomy Wound Manag. 55, 30–38 (2009) 18. Gildemeister, M.: Zur theorie des elektrischen Reizes. V. Polarisation durch Wechselströme. Berichte über die Verhandlungen der Sachsischen Akademie der Wissenschaften zu Leipzig. Math. Phys. Kl. 81, 303–313 (1930) 19. Laufer, Y., Elboim, M.: Effect of burst frequency and duration of kilohertz-frequency alternating currents and of low-frequency pulsed currents on strength of contraction, muscle fatigue, and perceived discomfort. Phys. Ther. 88, 1167–1176 (2008) 20. Ward, A.R., Robertson, V.J., Ioannou, H.: The effect of duty cycle and frequency on muscle torque production using kilohertz frequency range alternating current. Med. Eng. Phys. 26, 569–579 (2004) 21. Powell, J.H. et al.: Parameter selection and electrode placement of neuromuscular electrical stimulation apparatus. United States Patent 5358513 (1994) 22. Salama, G., Kanai, A., Efimov, I.R.: Subthreshold stimulation of Purkinje fibers interrupts ventricular tachycardia in intact hearts. experimental study with voltage-sensitive dyes and imaging techniques. Circ. Res. 74, 604–619 (1994) 23. Tobolova, M.: Microstimulator: Master’s Thesis. Brno University of Technology, Brno (2012) 24. Kaczmarek, P., et al.: Investigation of the relationship between stimulus parameters and a human muscle contraction force during stimulation of the gastrocnemius muscle. Artif. Organs 34, 126–135 (2009) 25. Tobolova, M., et al.: Testing the effects of micro-pulse stimulation on blood circulation using the thermodynamic sensors. J. Biosens. Bioelectron. 5, 1–7 (2014) 26. Nedvedova, M., Chmelar, M., Provaznik, I., Zuffova, K.: Exploring the therapeutic effects of micro-pulse stimulation. In: 1st International Conference on: Applied Physics, System Science and Computers, Dubrovnik (2016) | |
utb.fulltext.sponsorship | This work was supported by the Hybrid Integrated Technologies, Ltd., Brno University of Technology and European Regional Development Fund under the project CEBIA-Tech Instrumentation No. CZ.1.05/2.1.00/19.0376. | |
utb.wos.affiliation | [Nedvedova, Marie; Chmelar, Milan; Provaznik, Ivo] Brno Univ Technol, Fac Elect Engn & Commun, Dept Biomed Engn, Tech 3082 12, Brno 61600, Czech Republic; [Nedvedova, Marie] Tomas Bata Univ Zlin, Dept Elect & Measurements, Fac Appl Informat, Nad Stranemi 4511, Zlin 76005, Czech Republic; [Reznicek, Zdenek] Hybrid Integrated Technol Ltd, Nedachlebice 233, Nedachlebice 68715, Czech Republic | |
utb.scopus.affiliation | Faculty of Electrical Engineering and Communication, Department of Biomedical Engineering, Brno University of Technology, Technicka 3082/12, Brno, Czech Republic; Faculty of Applied Informatics, Department of Electronics and Measurements, Tomas Bata University in Zlin, Nad Stranemi 4511, Zlin, Czech Republic; Hybrid Integrated Technologies, Ltd, Nedachlebice 233, Nedachlebice, Czech Republic | |
utb.fulltext.projects | CZ.1.05/2.1.00/19.0376 |