Kontaktujte nás | Jazyk: čeština English
dc.title | Measurement of four-pane building window filled with a PCM | en |
dc.contributor.author | Koláček, Martin | |
dc.relation.ispartof | MATEC Web of Conferences | |
dc.identifier.issn | 2261-236X Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2017 | |
utb.relation.volume | 125 | |
dc.event.title | 21st International Conference on Circuits, Systems, Communications and Computers, CSCC 2017 | |
dc.event.sdate | 2017-07-14 | |
dc.event.edate | 2017-07-17 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | EDP Sciences | |
dc.identifier.doi | 10.1051/matecconf/201712502019 | |
dc.relation.uri | https://www.matec-conferences.org/articles/matecconf/abs/2017/39/matecconf_cscc2017_02019/matecconf_cscc2017_02019.html | |
dc.description.abstract | The transparent building element filled with Phase change materials (PCMs) represent an innovative solution that can achieve thermal comfort in buildings lowering the cooling and heating demand. There are many different PCMs which are used in the building element. Salt hydrates can absorb a large amount of energy and have properties similar to water. Nevertheless, these materials have a tendency to supercool (supercooling effect) and to incongruent melt. This paper reports the results of the measurement specific four-pane window filled with a PMCs. Thermal properties of the window were tested in the climate simulator where the climatic conditions were dynamically controlled. The measurement confirmed high thermal inertia of the window and also reducing heat transfer through the window. © The Authors, published by EDP Sciences, 2017. | en |
utb.faculty | Faculty of Applied Informatics | |
dc.identifier.uri | http://hdl.handle.net/10563/1007603 | |
utb.identifier.obdid | 43876508 | |
utb.identifier.scopus | 2-s2.0-85032871660 | |
utb.source | d-scopus | |
dc.date.accessioned | 2018-01-15T16:31:32Z | |
dc.date.available | 2018-01-15T16:31:32Z | |
dc.rights | Attribution 4.0 International | |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.rights.access | openAccess | |
utb.contributor.internalauthor | Koláček, Martin | |
utb.fulltext.affiliation | Martin Kolacek 1* 1 Tomas Bata University in Zlin, Faculty of Applied Informatics, Department of Automation and control Engineering, Nad Stranemi 4511, Zlin, Czech Republic. * Corresponding author: kolacek@fai.utb.cz | |
utb.fulltext.dates | - | |
utb.scopus.affiliation | Tomas Bata University in Zlin, Faculty of Applied Informatics, Department of Automation and Control Engineering, Nad Stranemi 4511, Zlin, Czech Republic | |
utb.fulltext.faculty | Faculty of Applied Informatics | |
utb.fulltext.ou | Department of Automation and Control Engineering |