Kontaktujte nás | Jazyk: čeština English
dc.title | Non-stationary behavior of roof drainage systems | en |
dc.contributor.author | Koláček, Martin | |
dc.relation.ispartof | MATEC Web of Conferences | |
dc.identifier.issn | 2261-236X Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2017 | |
utb.relation.volume | 125 | |
dc.event.title | 21st International Conference on Circuits, Systems, Communications and Computers, CSCC 2017 | |
dc.event.location | Crete Island | |
utb.event.state-en | Greece | |
utb.event.state-cs | Řecko | |
dc.event.sdate | 2017-07-14 | |
dc.event.edate | 2017-07-17 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | EDP Sciences | |
dc.identifier.doi | 10.1051/matecconf/201712502062 | |
dc.relation.uri | https://www.matec-conferences.org/articles/matecconf/abs/2017/39/matecconf_cscc2017_02062/matecconf_cscc2017_02062.html | |
dc.description.abstract | This paper reports the non-stationary behavior of a roof drainage during experimental measurement in the climate simulator. Many buildings use a fully or partially flat roof where it is necessary to use the roof drainage. Thermal behavior of roof drainage is very important from the point of view of heat transfer and potential condensation. The placement of a roof drain slightly deteriorates thermal transmittance of the roof. This experiment evaluates roof drains in the specific climate simulator where thermal conditions were dynamically controlled in the specific temperature range. The measurement was performed for two types of roof drains. The first drainage is a simple single-shell and the second is double-shell drainage. The results show the effect on the thermal transmittance of the roof section and also the minimal effect of condensation on the non-insulation part of the drainage. Both roof drains showed minimal deterioration of thermal transmittance of the roof construction. © The Authors, published by EDP Sciences, 2017. | en |
utb.faculty | Faculty of Applied Informatics | |
dc.identifier.uri | http://hdl.handle.net/10563/1007635 | |
utb.identifier.obdid | 43876509 | |
utb.identifier.scopus | 2-s2.0-85032863977 | |
utb.source | d-scopus | |
dc.date.accessioned | 2018-01-15T16:31:35Z | |
dc.date.available | 2018-01-15T16:31:35Z | |
dc.rights | Attribution 4.0 International | |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.rights.access | openAccess | |
utb.contributor.internalauthor | Koláček, Martin | |
utb.fulltext.affiliation | Martin Koláček 1* 1 Tomas Bata University in Zlin, Faculty of Applied Informatics, Department of Automation and control Engineering, Nad Stranemi 4511, Zlin, Czech Republic. * Corresponding author: kolacek@fai.utb.cz | |
utb.fulltext.dates | - | |
utb.scopus.affiliation | Tomas Bata University in Zlin, Faculty of Applied Informatics, Department of Automation and Control Engineering, Nad Stranemi 4511, Zlin, Czech Republic | |
utb.fulltext.faculty | Faculty of Applied Informatics | |
utb.fulltext.ou | Department of Automation and Control Engineering |