Kontaktujte nás | Jazyk: čeština English
dc.title | Thermal stability of bacteriocin nisin in polylactide-based films | en |
dc.contributor.author | Holčapková, Pavlína | |
dc.contributor.author | Hurajová, Anna | |
dc.contributor.author | Bažant, Pavel | |
dc.contributor.author | Pummerová, Martina | |
dc.contributor.author | Sedlařík, Vladimír | |
dc.relation.ispartof | Polymer Degradation and Stability | |
dc.identifier.issn | 0141-3910 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2018 | |
utb.relation.volume | 158 | |
dc.citation.spage | 31 | |
dc.citation.epage | 39 | |
dc.type | article | |
dc.language.iso | en | |
dc.publisher | Elsevier | |
dc.identifier.doi | 10.1016/j.polymdegradstab.2018.10.019 | |
dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S0141391018303306 | |
dc.subject | Nisin | en |
dc.subject | Polylactide | en |
dc.subject | Polyethylene glycol | en |
dc.subject | Thermal stability | en |
dc.subject | Biodegradable polymer | en |
dc.subject | Antibacterial | en |
dc.subject | Mass spectroscopy | en |
dc.description.abstract | This work investigates the thermal stability of bacteriocin nisin in polylactide (PLA) and polylactide/polyethylene glycol (PLA/PEG) blends at temperatures of 90 °C–180 °C. The samples were prepared by solvent cast technique and characterized according to their mechanical and thermal properties. Research on the thermal stability of nisin in the PLA and PLA/PEG systems was carried out by exposing the given films to various temperatures (90 °C, 120 °C, 160 °C, and 180 °C) for a duration of up to 48 h. Assessment of the antibacterial activity of the samples was carried out by the agar diffusion method against Micrococcus luteus, while structural analysis involved the use of high-performance liquid chromatography with mass detection. Structural changes in the polymer matrix were evaluated by gel permeation chromatography and scanning electron microscopy. The results showed that nisin retained almost 70% of its antimicrobial activity in the PLA matrix, even after treatment at 160 °C for 15 min. The presence of PEG significantly enhanced the degradation of nisin above 120 °C. © 2018 The Authors | en |
utb.faculty | University Institute | |
dc.identifier.uri | http://hdl.handle.net/10563/1008292 | |
utb.identifier.obdid | 43879409 | |
utb.identifier.scopus | 2-s2.0-85055704819 | |
utb.identifier.wok | 000452930600004 | |
utb.identifier.coden | PDSTD | |
utb.source | j-scopus | |
dc.date.accessioned | 2019-01-03T12:31:42Z | |
dc.date.available | 2019-01-03T12:31:42Z | |
dc.description.sponsorship | Ministry of Agriculture of the Czech Republic [QJ1310254]; Ministry of Education, Youth and Sports of the Czech Republic [LO1504]; Internal Grant Agency of Tomas Bata University in Zlin [IGA/CPS/2018/003] | |
dc.rights | Attribution-NonCommercial-NoDerivs 4.0 International | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.rights.access | openAccess | |
utb.ou | Centre of Polymer Systems | |
utb.contributor.internalauthor | Holčapková, Pavlína | |
utb.contributor.internalauthor | Hurajová, Anna | |
utb.contributor.internalauthor | Bažant, Pavel | |
utb.contributor.internalauthor | Pummerová, Martina | |
utb.contributor.internalauthor | Sedlařík, Vladimír | |
utb.fulltext.affiliation | Pavlina Holcapkova, Anna Hurajova, Pavel Bazant, Martina Pummerova, Vladimir Sedlarik * Centre of Polymer Systems, University Institute, Tomas Bata University in Zlin, Tr. T. Bati 5678, 76001, Zlin, Czech Republic * Corresponding author. E-mail address: sedlari@utb.cz (V. Sedlarik). | |
utb.fulltext.dates | Received 10 January 2018 Received in revised form 25 June 2018 Accepted 23 October 2018 Available online 26 October 2018 | |
utb.wos.affiliation | [Holcapkova, Pavlina; Hurajova, Anna; Bazant, Pavel; Pummerova, Martina; Sedlarik, Vladimir] Tomas Bata Univ Zlin, Univ Inst, Ctr Polymer Syst, Tr T Bati 5678, Zlin 76001, Czech Republic | |
utb.scopus.affiliation | Centre of Polymer Systems, University Institute, Tomas Bata University in Zlin, Tr. T. Bati 5678, Zlin, 76001, Czech Republic | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.ou | Centre of Polymer Systems | |
utb.fulltext.ou | Centre of Polymer Systems | |
utb.fulltext.ou | Centre of Polymer Systems | |
utb.fulltext.ou | Centre of Polymer Systems | |
utb.fulltext.ou | Centre of Polymer Systems |