Kontaktujte nás | Jazyk: čeština English
dc.title | Adaptive control of nonlinear processes: Continuous-time versus delta model parameter estimation | en |
dc.contributor.author | Dostál, Petr | |
dc.contributor.author | Bobál, Vladimír | |
dc.contributor.author | Gazdoš, František | |
dc.relation.ispartof | IFAC Proceedings Volumes (IFAC-PapersOnline) | |
dc.identifier.issn | 1474-6670 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2004 | |
utb.relation.volume | 37 | |
utb.relation.issue | 12 | |
dc.citation.spage | 273 | |
dc.citation.epage | 278 | |
dc.event.title | 2004 IFAC Workshop on Adaptation and Learning in Control and Signal Processing, ALCOSP 2004 and IFAC Workshop on Periodic Control Systems, PSYCO 2004 | |
dc.event.location | Yokohama | |
utb.event.state-en | Japan | |
utb.event.state-cs | Japonsko | |
dc.event.sdate | 2004-08-30 | |
dc.event.edate | 2004-09-01 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | International Federation of Automatic Control (IFAC) | |
dc.identifier.doi | 10.1016/S1474-6670(17)31480-5 | |
dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S1474667017314805 | |
dc.subject | Adaptive control | en |
dc.subject | Continuous-time model | en |
dc.subject | Delta model | en |
dc.subject | Parameter estimation | en |
dc.subject | Polynomial method | en |
dc.description.abstract | The paper deals with continous-time adaptive control of nonlinear processes. A nonlinear model of the process is approximated by a continuous-time external linear model. the parameters of the CT external linear model of the process are estimated in two ways. In the first case, direct estimation of the CT model is used. In the second case, the parameters of a corresponding delta model are recursively estimated. the 2DOF control system configuration is considered. the controller design is based on the polynomial approach. the resulting proper controller ensures stability of the control system as well as asymptotic tracking of the step reference and step load disturbance attenuation. the adaptive control is tested on the nonlinear system represented by a model of two spheric liquid tanks in series. Copyright © 2004 IFAC | en |
utb.faculty | Faculty of Technology | |
dc.identifier.uri | http://hdl.handle.net/10563/1008636 | |
utb.identifier.rivid | RIV/70883521:28110/04:63502302!RIV05-GA0-28110___ | |
utb.identifier.obdid | 12052656 | |
utb.identifier.scopus | 2-s2.0-85014885319 | |
utb.source | d-scopus | |
dc.date.accessioned | 2019-07-08T11:59:59Z | |
dc.date.available | 2019-07-08T11:59:59Z | |
utb.contributor.internalauthor | Dostál, Petr | |
utb.contributor.internalauthor | Bobál, Vladimír | |
utb.contributor.internalauthor | Gazdoš, František | |
utb.fulltext.affiliation | Petr Dostál, Vladimír Bobál, František Gazdoš Department of Process Control, Faculty of Technology, Tomas Bata University in Zlín, Nám. T. G. Masaryka 275, 762 72 Zlín Czech Republic Phone: +420 57 6033217; Fax: +420 57 6033333; E-mail: dostalp@ft.utb.cz | |
utb.fulltext.dates | - | |
utb.scopus.affiliation | Department of Process Control, Faculty of Technology, Tomas Bata University in Zlín, Nám. T. G. Masaryka 275, Zlín, 762 72, Czech Republic | |
utb.fulltext.faculty | Faculty of Technology | |
utb.fulltext.faculty | Faculty of Technology | |
utb.fulltext.faculty | Faculty of Technology | |
utb.fulltext.ou | Department of Process Control | |
utb.fulltext.ou | Department of Process Control | |
utb.fulltext.ou | Department of Process Control |