dc.title Mathematical function using mechanical properties to calculate chain scission as a function of radiation dose in electron beam treated styrene-butadiene-styrene block copolymer en
dc.contributor.author Datta, Sanjoy
dc.contributor.author Peter, Ondřej
dc.contributor.author Harea, Evghenii
dc.contributor.author Stoček, Radek
dc.contributor.author Naskar, Kinsuk
dc.relation.ispartof Express Polymer Letters
dc.identifier.issn 1788-618X Scopus Sources, Sherpa/RoMEO, JCR
dc.date.issued 2024
utb.relation.volume 18
utb.relation.issue 9
dc.citation.spage 911
dc.citation.epage 920
dc.type article
dc.language.iso en
dc.publisher Budapest Univ Technol & Econ
dc.identifier.doi 10.3144/expresspolymlett.2024.68
dc.relation.uri http://www.expresspolymlett.com/issue.php?y=2024&n=9
dc.subject electron beam radiation en
dc.subject thermoplastic elastomer en
dc.subject chain scission en
dc.subject cross-link density en
dc.subject tensile and tear strength en
dc.description.abstract Electron beam (EB) treatment of a high vinyl styrene-butadiene-styrene (SBS) block copolymer was accomplished by exposing the polymer to high-energy electrons generated from an electron accelerator. This resulted in the formation of free radicals of carbon on the polybutadiene units in the backbone of the elastomer and subsequent radical coupling to produce cross-links. In the process, some unavoidable chain scission (CS) also occurred. An attempt was made to mathematically trace the nature of the CS as a function of radiation dose with the aid of the experimentally determined cross-link density (CLD), tensile strength and tear strength, the latter three also obtained as functions of radiation dose. The radiation dose was varied from 12.5 to 300.0 kGy in multiples of 12.5 kGy. The novelty of the work was, in part to create a function that can be used to calculate chain-scission in dependence of EB radiation dose. It was found that a change in the ratio of CS to CLD occurred as a function of radiation dose over the previously calculated constant ratio, using the Charlesby-Pinner equation. en
utb.faculty University Institute
dc.identifier.uri http://hdl.handle.net/10563/1012180
utb.identifier.obdid 43885781
utb.identifier.scopus 2-s2.0-85201008249
utb.identifier.wok 001272696600004
utb.source J-wok
dc.date.accessioned 2025-01-15T08:08:12Z
dc.date.available 2025-01-15T08:08:12Z
dc.description.sponsorship Ministry of Education, Youth and Sports of the Czech Republic - DKRVO [RP_CPS_2024_28_006]
dc.description.sponsorship DKRVO; Ministerstvo Školství, Mládeže a Tělovýchovy, MŠMT, (RP_CPS_2024_28_006)
utb.ou Centre of Polymer Systems
utb.contributor.internalauthor Datta, Sanjoy
utb.contributor.internalauthor Peter, Ondřej
utb.contributor.internalauthor Harea, Evghenii
utb.contributor.internalauthor Stoček, Radek
utb.fulltext.sponsorship This work was supported by the Ministry of Education, Youth and Sports of the Czech Republic - DKRVO (RP_CPS_2024_28_006) .
utb.wos.affiliation [Datta, Sanjoy; Peter, Ondrej; Harea, Evghenii; Stocek, Radek] Tomas Bata Univ Zlin, Univ Inst, Ctr Polymer Syst, Tr Tomase Bati 5678, Zlin 76001, Czech Republic; [Peter, Ondrej] Bonatrans Grp as, \, Revolucni 1234, Bohumin 73581, Czech Republic; [Naskar, Kinsuk] Indian Inst Technol Kharagpur, Rubber Technol Ctr, Kharagpur, India
utb.scopus.affiliation Centre of Polymer Systems, University Institute, Tomas Bata University in Zlín, tř. Tomáše Bati 5678, Zlín, 760 01, Czech Republic; Bonatrans Group a.s, Revoluční 1234, Bohumín, 735 81, Czech Republic; Rubber Technology Centre, Indian Institute of Technology Kharagpur, Kharagpur, India
utb.fulltext.projects RP_CPS_2024_28_006