Kontaktujte nás | Jazyk: čeština English
Název: | Calibration of low-cost triaxial magnetometer | ||||||||||
Autor: | Kunčar, Aleš; Sysel, Martin; Urbánek, Tomáš | ||||||||||
Typ dokumentu: | Článek ve sborníku (English) | ||||||||||
Zdrojový dok.: | MATEC Web of Conferences 20th International Conference on Circuits, Systems, Communications and Computers (CSCC 2016). 2016, vol. 76 | ||||||||||
ISSN: | 2261-236X (Sherpa/RoMEO, JCR) | ||||||||||
Journal Impact
This chart shows the development of journal-level impact metrics in time
|
|||||||||||
DOI: | https://doi.org/10.1051/matecconf/20167605008 | ||||||||||
Abstrakt: | Heading angle of magnetic compasses is estimated using the triaxial magnetometer readings. The accuracy of these readings is influenced by many factors such as sensor errors (scale factors, non-orthogonality, and offsets), and magnetic deviations (soft-iron and hard-iron interference). To calculate the true heading angle, the magnetic calibration of magnetometer is necessary. This research paper describes a calibration procedure for triaxial low-cost MEMS magnetometer. The proposed calibration method determines twelve calibration parameters in 3D arbitrary rotations of magnetometer. | ||||||||||
Plný text: | https://www.matec-conferences.org/articles/matecconf/abs/2016/39/matecconf_cscc2016_05008/matecconf_cscc2016_05008.html | ||||||||||
Zobrazit celý záznam |